Maintenance; Back-Up Light Switch, Neutral Switch Replacement - Honda Acura NSX 1991 Service Manual

Table of Contents

Advertisement

Maintenance

NOTE: Check with the oil at operating temperature,
engine OFF, and the car on level ground.
1 .
Remove the oil filler plug, then check the level and
condition of the oil.
2.
The oil level must be up to the fill hole. If it is below
the hole, add oil until it runs out, then reinstall the
oil filler plug.
3.
If the oil is dirty, remove drain plug and drain
transmission.
4.
Reinstall the drain plug with a new washer, and
refill to proper level.
5.
Reinstall the oil filler plug with a new washer.
NOTE: The drain plug washer should be replaced
at every oil change.
Oil
Capacity
(2.9
2.7 e
U.S. qt.) after drain.
2.8 P (3.0 U.S. qt.) after qverhaul.
only SAEI OW-30 or 1 OW-40, that exceeds
Use
SE grade.
OIL FILLER PLUG
45 N*m (4.5,lym, 33 lb-ft)
DRAIN'PLUG
40
kg-m, 29 lb-ft)
Back-up Light Switch,
Neutral Switch
Proper Level.
.
NOTE: To check the switch, see section 23.
1 .
Disconnect the connector, then remove the switch
connector from the connector clamp.
2.
Remove the switch.
3.
Apply liquid gasket (P/N0871 8-550000 OE) to
the switch threads, then install the switch.
BACK-UP LIGHT SWITCH
25 N*m (2.5 kg-m, 18 lb-ft)
25 Nom (2.5 kg-m, 18 lb-ft)
SWITCH
13-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents