Air Mix Control Motor
Disconnect the heater valve cable from the air mix
control
motor.
AIR MIX CONTROL
MOTOR
2. Remove the air mix control motor (3 screws, 1
connector).
AIR MIX CONTROL
MOTOR
3.
Install the air mix control motor in the reverse order
of removal. Then apply battery voltage (page 22-90)
and watch the door move.
Make sure that the air mix door moves smoothly
without binding.
Make sure the motor doesn't pull the air mix door
too far.
22-70
4.
If necessary, to adjust the heater valve cable;
HEATER VALVE
HEATER VALVE
CABLE
(page 22-90).
stop on the cable. Then snap the clamp down
over the housing.
mix control motor still moves smoothly without
binding.
STOP
CLA
AIR MIX CONTROL