TFTP
Reprogramming
MDS 05-4846A01, Rev. D
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8461-MDS-UP-SD9-MS2ES-Upgrade-Key-SD9-MS-to-SD9-ES.aspx
The TFTP Reprogramming screen contains settable parameters for
TFTP file transfers and selections for Importing/Exporting configura-
tion files via TFTP.
—Use this field to enter a valid IP address for the host com-
Host IP
puter (where the configuration file resides).
—This field is used to enter the exact name of the configura-
File
tion text file that will be used by the radio to import or export con-
figuration data.
—Determines the amount of time (in seconds) that the
Timeout
radio should wait for a TFTP server to respond. The default set-
ting is 10 seconds, and will not normally require any change. If a
change is needed, enter a new timeout value in this field.
When all of the above fields have been set and you are ready to load a
new configuration file, click the
ming.
This screen may be updated on demand by clicking the
It may also be refreshed automatically by clicking the
time (in seconds) may be entered for automatic refresh in the box to the
right of the
button.
Auto
SD Series Technical Manual
button to begin reprogram-
Retrieve File
Refresh
Auto
button.
button. A