Link Test

MDS 05-4846A01, Rev. D
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8461-MDS-UP-SD9-MS2ES-Upgrade-Key-SD9-MS-to-SD9-ES.aspx
The primary use of the Link Test is to verify that a specific radio's set-
tings are consistent with the initiator including: Assigned frequency,
unit number setting, encryption (if enabled), etc. Also collected at the
same time is an indication of link quality. All radios are always ready to
respond to a Link Test message. Only the initiating radio requires con-
figuration when using the Link Test screen, and it is only available when
operating in packet mode.
A summary of data statistics is displayed on the right side of the screen,
including transmit/receive packet counts, total bits, and total number of
bit errors.
NOTE: No other data traffic should be active when performing a Link-
test.
Destination Unit Address
being tested.
—Enter the number of times for the message to be
Linktest Count
sent across the radio link.
Response Timeouts (msec)
will result in a timeout if no response is received in within that
period.
—Set this box to
Start Test
the test.
When you are done with the settings above, press
apply the changes.
—Clicking this button updates the displayed statistics on
Refresh
demand.
—Initiates automatic updating of statistics. A time (in sec-
Auto
onds) may be entered in the box provided, to specify how often
the display is updated.
SD Series Technical Manual
—Enter the Unit Address of the other radio
—Enter the time (in milliseconds) that
to start the Link Test, or
ON
Commit Configuration
to stop
OFF
to
59