Table 15. Event Codes (Continued)
Event
Event
Code
Class
Description
010
Major
Flash write failure.
011
Major
Checksum fault.
012
Major
Receiver time-out. No data received within the specified
receiver time-out time.
013
Major
Transmitter time-out.
014
Major
#14 Reserved.
015
Major
VSWR fault. Possible antenna/feedline problem.
068
Major
Excessive Ethernet traffic on interface.
016
Minor
Unit address not programmed.
017
Minor
Data parity error. This usually indicates a parity setting
mismatch between the radio and the RTU.
018
Minor
Data framing error. May indicate a baud rate mismatch
between the radio and connected equipment.
019
Minor
#19 Reserved.
020
Minor
Configuration error.
021
Minor
#21 Reserved.
022
Minor
#22 Reserved.
023
Minor
#23 Reserved.
024
Minor
#24 Reserved.
025
Minor
6v regulator output not in valid range. If the voltage is too far
out of tolerance, operation may fail.
026
Minor
DC input voltage approaching limit. If the voltage is too far out
of tolerance, operation may fail.
027
Minor
#27 Reserved.
028
Minor
#28 Reserved.
029
Minor
RF Output Power not in valid range.
030
Minor
#30 Reserved.
031
Minor
Internal temperature approaching limit.
037
Minor
Unexpectedly executing APP 1.
038
Minor
Unexpectedly executing APP 2.
039
Minor
Boot error; active image unknown.
042
Minor
Reprogramming failure.
064
Minor
A socket operation failed.
070
Minor
AP not available.
041
Status
Forced restart of Ethernet interface.
043
Status
Reprogramming in progress.
SD Series Technical Manual
73