Remote mount

In applications where a remotely mounted display is required, the remote mount allows
the electronics housing to be mounted 3m away from the process connector. This can
be useful when access to the mounting location is limited. To assemble the remote
mount, attach the process connector first, followed by securing the mounting bracket to a
pipe or wall. Secure the electronics module to the bracket with the 3 supplied M6
screws. Connect the cable and check bends for minimum radius (see
Figure
15) to
prevent damage. Torque the 2 nuts to 6 Nm (4.4 ft-lbs).

Figure 15: Remote mount