Slg726 - Honeywell SLG 700 Quick Start Manual

Smartline level guided wave radar
Hide thumbs Also See for SLG 700:
Table of Contents

Advertisement

SLG726

Depending on the length of the probe there may be 0 to 3 2.0m rod segments.
Coaxial probes ≤ 2.0m are shipped with a single outer tube.
Coaxial probes ˃ 2.0m are shipped with the outer tube in segments.
Probe Length ≤ 2.0m
Step
1
2
3
Probe Length ˃ 2.0m
Step
1
2
December 2017
Action
Thread the nut onto the central conductor of the process
connector. Refer to Figure 3 for nut position on flanged process
connectors. Place a lock washer between the locknut and the first
rod segment. Torque the nut against the rod segment and lock
washer to secure the connection.
Note: Tighten rod connection point to the following torque:
SLG726 15 Nm (11 ft-lbs)
Slip the coaxial outer tube over the rod and tighten to the process
connector.
Note: Tighten rod connection point to the following torque:
SLG726 15 Nm (1 1ft-lbs)
It is recommended that a process compatible thread
locking compound (i.e. Loctite 242) be used on the
outer conductor threaded joints.
Install end spacer between central conductor and outer tube in
counterbore. Secure end spacer using the retaining ring.
Action
Thread the nut onto the central conductor of the process
connector. Refer to
connectors. Place a lock washer between the locknut and the first
rod segment. Torque the nut against the rod segment and lock
washer to secure the connection.
Note: Tighten rod connection point to the following torque:
SLG726 15 Nm (11 ft-lbs)
Slip the coaxial outer tube with internal threads over the rod and
tighten to the process connector.
Note: Tighten rod connection point to the following torque:
SLG726 15 Nm (11 ft-lbs)
It is recommended that a process compatible thread
locking compound (i.e. Loctite 242) be used on the
outer conductor threaded joints.
Quick Start Installation Guide
Figure 3
for nut position on flanged process
13

Advertisement

Table of Contents
loading