Slip the coaxial end segment over the rod end segment and secure
to coaxial coupler.
Note: Tighten rod connection point to the following torque:
11
Install the end spacer between central conductor and outer tube in
counterbore. Secure end spacer using the retaining ring.
12
Insert 2 M3 set screws into each coupler.
Note:
13
December 2017
SLG726 30 Nm (22 ft-lbs)
It is recommended that a process compatible thread
locking compound (i.e. Loctite 242) be used on the outer
conductor threaded joints.
Tighten M3 set screws to the 1.0 Nm (8.8 in-lb).
It is recommended that a process compatible thread
locking compound (i.e. Loctite 242) be used on each set
screw.
Figure 6: SLG726 Coaxial probe assembly
Quick Start Installation Guide
15