Testing & Certification - GE 869 Instruction Manual

Motor protection system
Hide thumbs Also See for 869:
Table of Contents

Advertisement

CHAPTER 1: INTRODUCTION
Testing & Certification
869 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUAL
REMOTE MODBUS DEVICE PROFILE
Device Name:........................................................BSG3 (13 alphanumeric characters maximum)
IP Address:..............................................................0.0.0.0 – standard Ethernet address
Slave Address: ......................................................254 (1 to 254)
Modbus Port:.........................................................502 (0 to 10000, default 502)
Poll Rate: .................................................................3 minute (OFF, 3 to 120 minutes), the continuous mode poll
Trigger:.....................................................................Off (any FlexLogic Operand), the trigger mode is based on
APPROVALS
Applicable Council Directive
CE compliance
Low voltage directive
EMC Directive
R&TTE Directive
North America
cULus
ISO
Manufactured under a registered
quality program
TESTING AND CERTIFICATION
Test
Dielectric voltage withstand
Impulse voltage withstand
Insulation resistance
Damped Oscillatory
Electrostatic Discharge
RF immunity
Fast Transient Disturbance
Surge Immunity
Conducted RF Immunity
Power Frequency Immunity
Voltage variation, interruption and
Ripple DC
Radiated & Conducted Emissions
Sinusoidal Vibration
Shock & Bump
Seismic
Power magnetic Immunity
Pulse Magnetic Immunity
Damped Magnetic Immunity
Voltage Dip & interruption
interval is defined as the poll rate interval
the FlexLogic operand designed to trigger the poll
According to
EN60255-27
EN60255-26
ETSI EN300 328 ETSI EN301 489-1 ETSI
EN301-489-17
UL508, e57838 NKCR, NRGU
C22.2.No 14, e57838 NKCR7, NRGU7
ISO9001
Reference Standard
EN60255-5/IEC60255-27
EN60255-5/IEC60255-27
IEC60255-27
IEC61000-4-18
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
IEC60255-26
IEC60255-26
CISPR11 /CISPR22
IEC60255-21-1
IEC60255-21-2
IEC60255-21-3
IEC61000-4-8
IEC61000-4-9
IEC61000-4-10
IEC61000-4-11
SPECIFICATIONS
Test Level
2.3 kV
5 kV
500 VDC
2.5 kV CM, 1 kV DM, 1 MHz
Level 4
Level 3
Class A and B
Level 3
Level 3
Class A & B
PQT levels based on
IEC61000-4-29,
IEC61000-4-11 and
IEC61000-4-17
Class A
Class 1
Class 1
Class 2
Level 5
Level 4
Level 4
0, 40, 70, 80% dips,
250/300 cycle interrupts
1–31