Maintenance Events and Alarms

MAINTENANCE (116)

For additional information, refer to
Server—Maintenance (116)" section on page
DESCRIPTION
Call Agent Reports the Congestion Level of the Feature Server (CA Reports the Congestion Level of
FS)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
Domain Name of FS–STRING [65]
Feature Server ID–STRING [20]
PRIMARY
The Feature Server is congested.
CAUSE
PRIMARY
No action is required.
ACTION
MAINTENANCE (117)
To troubleshoot and correct the cause of the alarm, refer to the
Fault—Maintenance (117)" section on page
DESCRIPTION
Side Automatically Restarting Due to Fault
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
Time of next restart attempt.–STRING [25]
PRIMARY
The platform has shut down due to the OOS-FAULTY state, and is in the process of being
CAUSE
automatically restarted.
PRIMARY
Capture the debugging information, especially from the saved.debug directory. This alarm indicates
ACTION
that an automatic restart is pending and at what time it will be attempted.