Chapter 10
Signaling Troubleshooting

SIGNALING (14)

To troubleshoot and correct the cause of the alarm, refer to the
(14)" section on page
DESCRIPTION
Link is Remotely Inhibited
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Link–ONE_BYTE
Link Name–STRING [8]
PRIMARY
Issued when the specified Signaling System 7 (SS7) link is inhibited at the remote end.
CAUSE
PRIMARY
Monitor the events at the network level for any related to the specified SS7 link. Restorative actions
ACTION
need to be taken on the remote end.
SIGNALING (15)
To troubleshoot and correct the cause of the alarm, refer to the
(15)" section on page
DESCRIPTION
Link is Locally Inhibited
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Link No–ONE_BYTE
Link Name–STRING [8]
PRIMARY
Issued when the specified SS7 link is inhibited at the local end.
CAUSE
PRIMARY
Verify that the SS7 signaling adapter process is running and that the SS7 interface card(s) are in
ACTION
service.
SECONDARY
If a component is found to be non-operational, restore it to service.
ACTION
OL-8723-19
10-133.
10-133.
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
Signaling Events and Alarms
"Link is Remotely Inhibited—Signaling
"Link is Locally Inhibited—Signaling
10-9