Chapter 6
Configuring the Cisco IOS XE In Service Software Upgrade Process
Command or Action
Step 1
Switch> enable
Step 2
Switch# configure terminal
Step 3
Switch(config)# issu set rollback-timer value
Step 4
Switch(config)# exit
Step 5
Switch# show issu rollback-timer
This example shows how to set the rollback timer to 3600 seconds:
Switch> enable
Switch# configure terminal
Enter configuration commands, one per line.
Switch(config)# issu set rollback-timer 3600
% Rollback timer value set to [ 3600 ] seconds
Switch(config)# exit
Switch# show issu rollback-timer
The Rollback Timer cannot be set in loadversion or runversion state, as the following example illustrates:
Switch# show issu state detail
Switch# show issu rollback-timer
Switch# configure terminal
Enter configuration commands, one per line.
Switch(config)# issu set rollback-timer 20
% ISSU state should be [ init ] to set the rollback timer
OL-25340-01
Rollback Process State = Not in progress
Configured Rollback Time = 60:00
RP State = Active
ISSU State = Load Version
Operating Mode = Stateful Switchover
Current Image = bootflash:old_image
Pre-ISSU (Original) Image = bootflash:old_image
Post-ISSU (Targeted) Image = bootflash:new_image
RP State = Standby
ISSU State = Load Version
Operating Mode = Stateful Switchover
Current Image = bootflash:new_image
Pre-ISSU (Original) Image = bootflash:old_image
Post-ISSU (Targeted) Image = bootflash:new_image
Rollback Process State = Not in progress
Configured Rollback Time = 60:00
Software Configuration Guide—Release IOS XE 3.3.0SG and IOS 15.1(1)SG
Purpose
Enables privileged EXEC mode.
Enter your password if prompted.
Enters global configuration mode.
Configures the rollback timer value, which can range from
0 to 7200.
Returns the user to privileged EXEC mode.
Displays the current setting of the ISSU rollback timer.
End with CNTL/Z.
Slot = 5
Slot = 6
End with CNTL/Z.
How to Perform the ISSU Process