3
Transition
Cropping
y
"Dead Zone"
(%)
100
0
[Last 30%]
t: transition execution time
y: change in transition and cropping amount
DME Wipe Modify Clear
Press [Default Recall] at the lower left of the menu display, turning it on, then
press VF6 'DME Wipe' to return the DME wipe settings to their initial status.
For details of menu operations, see "Menu Operations" (page 283).
422
Basic Procedure for DME Wipe Settings
The Remove From Begin menu appears.
In the <Release Transition> group, select the timing of transition
completion.
Last30%: The transition completes at the end of 70% of the transition
execution time. The transition has a dead zone from 70% to 95% of the
transition time.
Last5%: The transition completes at the end of 95% of the transition
execution time. When the transition completes, the cropping is
removed during the last 5%.
Off: The transition completes at the end of the transition execution time.
During the last 5% of the transition, the transition and cropping
removal proceed together.
y
(%)
100
t
0
70
95
100 (%)
Transition
Cropping
(%)
100
t
70
95
100 (%)
[Last 5%]
Transition
Cropping
y
95
0
95
100 (%)
[Off]
t