This confirms the entry, and the selected region name and the set transition
rate appear in the numeric keypad control block display.
The transition control block display of the same bank (M/E or PGM/PST)
also shows the setting.
To enter a difference from the current value
After pressing the [+/–] button, enter the difference and press the [TRIM]
button.
To change the sign (+ or –), press the [+/–] button.
Setting the transition rate by a menu operation
1
In the M/E or PGM/PST menu, select first VF7 'Misc,' then HF1
'Transition.'
The Transition menu appears.
2
Select any transition type in the <Transition Type> group.
3
Turn the knob to set the transition rate.
Knob
1
Displaying the transition rates in a menu and changing the
settings
For each of the M/E and PGM/PST banks, you can display the transition rate,
independent key transition rate and fade-to-black transition rate, and change
the settings.
For more details, see "Displaying a List of Transition Rates and Changing the
Settings" (page 487).

Pattern Limit

There are two ways of setting a pattern limit: either by operating the fader lever
to save the fader position, or by using the Wipe menu or DME Wipe menu to
access the Edge/Direction menu for the M/E or PGM/PST bank.
For an overview of the pattern limits, see page 43.
Parameter
Adjustment
Transition Rate
Transition Rate
Setting values
0 to 999 (frame count)
Executing a Transition
315