Sony Tektronix VX4792 User Manual page 158

Arbitrary waveform generator
Table of Contents

Advertisement

Arguments
Examples
TRIGger:INPut (?)
Group
Related Commands
Syntax
Arguments
Examples
VX4792 User Manual
HIGH — selects high impedance: 1 MW
LOW — selects low impedance: 50 W
:TRIGGER:IMPEDANCE LOW
selects low impedance.
The TRIGger:INPut command selects the trigger source. The TRIGger:INPut?
query returns the currently selected trigger source.
MODE
TRIGger:OUTPut, CLOCk:SOURce
TRIGger:INPut { INTernal | ECLTRIG0 | ECLTRIG1 }
TRIGger:INPut?
TRIGger
:
INTernal — selects the internal trigger signal as the trigger
ECLTRIG0 — selects the VXIbus signal ECLTRIG0 as the trigger
ECLTRIG1 — selects the VXIbus signal ECLTRIG1 as the trigger
:TRIGGER:INPUT INTERNAL
selects the internal trigger signal as the trigger. In this example, the module
becomes the trigger master for synchronous operation.
<Space>
INPut
Command Descriptions
INTernal
ECLTRIG0
ECLTRIG1
?