Command Descriptions
OUTPut:SYNC (?)
Group
Related Commands
Syntax
Arguments
Examples
*RST
Group
Related Commands
Syntax
Arguments
Examples
3-64
The OUTPut:SYNC command selects a point on the waveform at which the sync
signal is generated and output at the SYNC connector on the front panel. The
OUTPut:SYNC? query returns the currently selected position.
OUTPUT
None
OUTPut:SYNC { START | END }
OUTPut:SYNC?
OUTPut
:
START — generates a sync signal when a waveform is triggered
END — generates a sync signal at the end of a waveform
:OUTPUT:SYNC END
sets the sync signal to output at the end of a waveform.
The *RST common command resets the waveform generator to the default state
(default values are listed in Appendix C).
SYSTEM
None
*RST
*RST
None
*RST
resets the instrument.