Sony Tektronix AWG2021 Service Manual page 97

Arbitrary waveform generator
Table of Contents

Advertisement

Check Internal Add
Operation (Option 02
Only)
AWG2021 Service Manual
Electrical
Arithmetic Operation, Add, on page 1-13.
Characteristic
Checked
Equipment
Two 50 W coaxial cables
Required
One function generator
One digital multimeter (DMM)
Prerequisites
The AWG2021 meets the prerequisites listed on page 4-7. Option 02
(CH2 output channel) must be installed in the AWG2021.
1. Use the test hookup and control settings from the previous check.
2. Check internal Add operation:
a. Check Autostep Step 4:
H Push the AWG2021 MANUAL TRIGGER button, and check that
the step changes to Step: 4 on the MODE menu.
H Check that the DMM reading is in the range from +2.85 V to
+3.15 V.
3. End procedure:
a. Disable function generator output: Turn off the function generator
output.
b. Remove equipment: Disconnect connections to the test equipment.
Performance Tests
4-29