Table 6- 13
Technical data for Motor Modules, 510 ... 720 V DC (line voltage 380 ... 480 V3 AC), Part 3
Article number
Type rating
- Based on I
(50 Hz 400 V)
L
- Based on I
(50 Hz 400 V)
H
- Based on I
(60 Hz 460 V)
L
- Based on I
(60 Hz 460 V)
H
Output current
- Rated current I
N A
- Base load current I
L
- Base load current I
H
- Max. output current I
max A
DC link current
Rated current I
when fed via
N DC
- Basic Line Module
- Active Line Module
Base load current I
when fed via
L DC
- Basic Line Module
- Active Line Module
Base load current I
when fed via
H DC
- Basic Line Module
- Active Line Module
Supply voltages
- Electronics power supply
- DC link voltage
- Output voltage
DC link capacitance
Rated pulse frequency
- Max. pulse frequency without derating
- Max. pulse frequency with derating
Electronics current consumption (24 V DC)
Cooling method
Power loss, max.
3)
- At 50 Hz 400 V
- At 60 Hz 460 V
- Dissipated to the ambient air
Max. coolant temperature
- without derating
- with derating
Rated flow rate
Pressure drop, typical
at the rated flow rate
4)
Liquid volume of integrated heat exchanger
Sound pressure level
L
(1 m) at 50/60 Hz
pA
226
6SL3325–
kW
1)
kW
1)
HP
2)
HP
2)
A
A
A
A
A
A
A
A
A
A
V
DC
V
DC
V
ACrms
μF
kHz
kHz
kHz
A
kW
kW
kW
°C
°C
l/min
Pa
dm³
dB(A)
1TE41–2AA3
1TE41–4AA3
710
800
630
710
1000
1000
900
1000
1260
1405
1230
1370
1127
1257
1845
2055
1512
1714
1361
1544
1474
1670
1326
1500
1345
1532
1211
1377
24 (20.4 ... 28.8)
0 to 0.72 x DC link voltage
29000
29000
1.25
1.25
1.25
1.25
7.5
7.5
1.46
1.46
Liquid cooling with integrated aluminum heat exchanger
9.15
10.2
10.05
11.2
0.56
0.62
45
45
50
50
27
27
70000
70000
1.56
1.56
56
56
Manual, (GH7), 11/2016, 6SL3097-4AM00-0BP7
1TE41–4AS3
7)
800
630
1000
900
1330
1310
1150
2055
1550
1403
1525
1405
1676
1403
510 ... 720
21000
2
2
4
1.46
10.9
12.3
0.65
45
50
27
70000
1.56
56