10.4 Data Switch Timing According to Data Reset Conditions

The data switch timing differs depending on the setting configured by selecting "Parallel Reset Condition" from
the ENVIRONMENT menu > "Parallel Communication". The following parallel reset conditions are selectable.
Hold (default value)
Off After Read
Off Before Read
Example operation
If „"OK" inspection results are consecutively output, the terminals D1 to D8 function according to the parallel rest
condition. Refer to the following descriptions for more information on parallel reset conditions.

10.4.1 Reset Condition: Hold

"Hold" is the way of continuously outputting data. The data are output by being switched at the time of the end of
the inspection (therefore, if the previous and current inspection results are ON, the data will be retained and
output will not be turned off).
When an error occurred, the ERROR signal ON and OFF timing is synchronized with the output data (D1 to
D8).
248
Not reset, but output is retained.
Reset the previous output after capturing an image
Reset the previous output before capturing an image
Hold the data.
Reset the data.
Select if you want to extend the data
output time as much as possible.
Reset the data.
If you want to extend the data OFF time
as much as possible or if processing
time is too short for the external device
to recognize the terminal D1 was turned
OFF.