Item
Image
Camera 1
Output
Camera 2
Setting
Destination
Output
Operation
Output
Condition
Output
interval
Output
signal(Err)
at error
Forced
outage at
error
Header
Additional
information
1 -4
Conversion
CV1 to CV4
Data
Data
Output Setting
Output
(General
Settings
Output)
Scan
Judgment
Num. Calcu
Statistics
Option
(Initial value: With
Function
an underline)
Out/None
To output images captured by Cameras 1 and 2 to a
Compact Flash memory card or PC via Ethernet.
Out/None
Ethernet
To output an image to the PC in which the designated
software is installed via Ethernet.
CF
To output an image the PC in which a Compact Flash
memory card is inserted
Sync. /Async.
Select whether or not to output an image within the
inspection time.
Per Start
To output an image per inspection
Total Judgment
To output the image that was totally judged as NG.
Customize output
To output images at intervals of the specified time.
interval
2 – 10000
This function is effective if you want to let the PV310
output images at the interval that is set as "Customize
output interval".
Images are output every time inspection is executed.
OFF / ON
Outputs an error-signal when an error occurred in
image outputting through Ethernet.
OFF / ON
Pauses inspections and displays a message on the
monitor when an error occurred in image outputting
through Ethernet.
1 – 16 letters
Specify the header at the destination where an image
is output. Initial value: Image
None/Year-Month
Select the information to be added to a file name
-Day/Time-Minute
File name = "Header", "Additional Information 1_",
-Second/Total
"Additional Information 2_", "Additional Information 3_",
Judgment/ Type
"Additional Information 4_" and ".bmp (extension)"
No.
---
To convert the units of calculation results.
For example, unit conversion from pixel to mm
Not Output
To cancel inspection result output
Serial (Per
Outputs the data of scan, judgment, numeric
Start)/Computer
calculation or statistics that have been set to output to
Link/Serial
the selected external device
(Async.)/Ethernet/
Card
Out/None
To output the number of scans to the external device.
Out/None
Outputs all of the judgment data that has been set to
output the external device by selecting "TOOL" >
"Calcu.-Stat.-Output" > "Judgment"
Out/None
Outputs the numeric calculation data that has been set
to output to the external device by selecting "TOOL" >
"Calcu.-Stat.-Output" > "Num. Calcu"
Out/None
Outputs the statistics data that has been set to output
to the external device by selecting "TOOL" >
"Calcu.-Stat.-Output" > Statistics"
Ref.
page
232
237
236
178