8.6.4 "Automatic Switch" Execution Mode

Blocks of inspection execution
The data of the checkers, Numeric Calculation formulas and Judgment formulas stored in each product type are
divided into three blocks in numeric order. Each block is called a "block 1", "block 2, or "block 3".
Block
Checker
1
No.1 – 32
2
No.33 – 64
3
No.65 – 99
After the block 1 was executed, if the result of JD32 of block 1 is judged as OK, then block 2 is executed. If the
result of block 1 is judged as NG, then block 3 is executed.
Execution order
Inspection start
Execution of block 1
Output of the result of Judgment formula JD32
Judged as OK
Execution of block 2
Execution of statistics
(Only the checkers, Numeric Calculation formulas or
Judgment formulas of blocks 1 and 2 that are set as
"objects" are executed.)
Output of the result
(Block 2 and Statistics data)
To check the number of the last executed block:
The number of the block that was executed last is displayed in the status display area.
212
Numeric
Judgment
Calculation
CA01 – CA32
JD01 – JD32
CA33 – CA64
JD33 – JD64
CA65 – CA96
JD65 – JD96
Judged as NG
Execution of block 3
Execution of statistics
(Only the checkers, Numeric Calculation formulas or
Judgment formulas of blocks 1 and 3 that are set as
"objects" are executed.)
Output of the result
(Block 3 and Statistics data)