Parameter Object, Instance Number: 401 hex ... 43E hex
Supported services
Class
Table 6- 53
No.
1
2
3
Parameter access to drive object 0 (DO 0) is realized via this class.
The class structure is analog to 401 hex. Drive object (DO) is selected via the class number.
Example:
0x401 -> DO 1
0x402 -> DO 2
...
0x43E -> DO 62
6.11.5

Integrate the drive device into the Ethernet network via DHCP

Integrating the drive into an Ethernet network
Proceed as follows to integrate the drive into Ethernet:
1. Set p8944 (CBE2x DHCP mode) = 2 or 3.
– p8944 = 2: The DHCP server assigns the IP address based on the MAC address.
– p8944 = 3: The DHCP server assigns the IP address based on the station name.
2. Save the settings with p8945 = 2.
When it is switched on the next time, the drive retrieves the IP address made available by a
DHCP. You can address the drive as Ethernet node.
Displays
● r8950: Station name of the CBE20
● r8954: DHCP mode of the CBE20
● r8955: MAC address of the CBE20
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
• Get Attribute all
• Get Attribute single
Class Attribute
Service
Type
get
UINT16
get
UINT16
get
UINT16
Instance
Name
-
Max slot num
Max slot ID
6.11 Communication via EtherNet/IP
• Get Attribute all
• Set Attribute single
Operation
395