4 - 74
Basic PRI Call Control (BCC)
Display of incoming caller's name and number (when allowed by the
telco)
Speech and 3.1 KHz audio
When installed, GCD-PRTA uses the first block of 32 consecutive
trunk ports. For example, if a COIU blade is installed for trunks 1~8,
the GCD-PRTA automatically uses trunks 9~40. If the COIU blades
are installed for trunks 1~8 and 17~24, GCD-PRTA uses trunks
25~56. The GCD-PRTA cannot use trunks 9~16 (even if available)
since they are not part of a consecutive block of 32 trunks. Each
GCD-PRTA requires 32 ports in the system, even if not all the ports
are used, otherwise the blade does not function.
The GCD-PRTA requires one universal slot.
Table 4-39 GCD-PRTA Maximum Upgrade Capacities
maximum capacities for the GCD-PRTA blades when they are
upgraded.
Table 4-39 GCD-PRTA Maximum Upgrade Capacities
19" Chassis
with CPU
3
5.6.2

Installation

To install the GCD-PRTA:
1.
Plug the GCD-PRTA into any universal slot on the chassis.
2.
Use Program 10-51-01 (PRI/T-1) to set the GCD-PRTA blade
to either PRI.
3.
Connect the cable from the NT1 Network Termination cable to
the CN2 connector on the GCD-PRTA. (Refer to
PRI Layout for NT-1 Network on page 4-75
19" Chassis
19" Chassis
without CPU
3
With normal operation, LED 1 flashes green.
UNIVERGE SV9100
provides the
Networked
x4
Chassis
6
8
Figure 4-20
for a cabling
Installing the SV9100 Blades