NEC Univerge SV9100 Hardware Manual page 175

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

UNIVERGE SV9100
.
System Hardware Manual
2.
Push down on the battery, opposite from the plus (+) symbol
(refer to
Figure 4-5 GCD-CP10 Battery
Battery Removal
1.
Ensure backup of SRAM data on GCD-CP10
When removing the backup battery, SRAM data and system
clock are initialised. Use the following to store the SRAM data
(Reconfigure the system clock after replacing the battery).
Table 4-5 SRAM Data Types
SRAM Data
Read the fault information using the PCPro "Fault
Fault Information
Save the memory by specifying "DBM data (PHS/OAI)"
OAI FLF Memory
in the PCPro "System Data Save/Load Verify" menu.
Billing Memory
Print the billing memory using an external printer.
SMDR Billing Data
2.
Power off the system and remove the GCD-CP10 from the
chassis.
Before removing the GCD-CP10 from the
chassis to install or replace a battery,
ensure the system is powered Off.
When removing the backup battery,
SRAM data and system clock are
initialized. Make a backup of the SRAM in
advance and configure the system clock
after battery replacement.
Replace the battery every 6 years.
Contact the reseller where you bought the
product for a replacement battery.
The following SRAM data types are important
for the client. If stored, this procedure must be
used to restore the data.
Billing memory
SMDR Billing data
Measure
Display" menu.
Delete the billing data using SMDR/CR1000.
Issue 1.2