Sharp IV-S20 User Manual page 63

Compact image sensor camera
Table of Contents

Advertisement

Operation Examples (Point measurement)
Continued from the preceding page
4. Move the cursor to q UPPER MENU with the up and down keys, and press the SET key.
- The screen will return to the [TYPE00-MEAS1] (type: 00, measurement: 1) menu.
5. Press the ESC key.
- The screen will return to the [OBJECT TYPE COND] (conditions of object type) menu.
(8) Setting the final evaluation output condition
This setting is used to output the result of the final evaluation externally (see the following page).
- The final evaluation result is always output to the auxiliary relay C112. When the final
evaluation result is OK, C112 is ON, and when the result is NG, it is OFF. The result of final
3
evaluation can be externally output by using the auxiliary relay C112.
- The setting procedures are the same as described in item (9) in section 3-2 "position
measurement."
[PAGE0]
INPUT0
LOGIC
(9) Returning to the MAIN OPS MENU
1. Press the ESC key.
2. Press the ESC key.
- The screen will return to the MAIN OPS MENU.
Continued on the following page
0
1
2
C112
- The screen will return to the [SYSTEM SETUP] menu.
- Move the cursor to 9 SAVE IN FLASH MEM (save data in flash memory) or 0
OPERATIONS with the up and down keys, and press the SET key.
- The following message will be displayed on the upper corner of the screen.
DATA SAVE? (Do you want to save data ?) (YES=[MOVE]/NO=[ESC])
- Press the SET key.
- The data saving operation will start, and the progress will be displayed on the bottom
of the screen.
REFERENCE IMAGE
SYSTEM I/O
MEAS CONDITIONS
When the data has been saved in the IV-S20 flash memory, the display will change from
"SAVING" to "SAVING COMPLETE."
Note:
· If the ESC key is pressed, the settings you entered will not be saved in the IV-S20
flash memory. In this case, if the power to the IV-S20 main housing is turned OFF, or
if the type No. is changed, the settings will be deleted.
- If the cursor was moved to 0 OPERATIONS in step 1, the screen will automatically
return to the [MAIN OPS MENU].
3
4
5
6
7
OUT
Y00
SAVING
3-42