Degree of match inspection
From the previous page
[NUMERIC CALC]
1CALC. RESULT N00(0~15)
2OBJECT TYPE NO MATCH [M] CORD[X Y] LEVL[G]
3FORMULA
4UPPER&LOWER LIMIT 00000000.0~ +00000000.0
5OUTPUT
6RUN A TEST
7UPPER MENU
N00
N01
N02
N03
Numerical calculation
1CALC.RESULT
(calculation result)
2OBJECT TYPE(type)
9
3FORMULA
4UPPER&LOWER LIMIT
5OUTPUT
6RUN A TEST
(make a test run)
7UPPER MENU
· The number of formulas which can be set are dictated by the selections made in items 2 and 3
as follows.
Coordinates X/Y
Degree of match M
Light level G
Numerical calculation NC
Constant C
· For more information on numerical calculations see (section 9-2 [4] Numerical calculations).
Note: You must run a test using item 6 RUN A TEST before making any calculations.
Return to the [TYPE00-MEAS1 to 3] and select item 9 OUTPUT CONDITIONS (output condition).
Continued on the follwing page
(TYPE00-MEAS.1-DEG OF MATCH)
NUM-CALC[NC] CNST[C]
REG.00(0~15) MDL0(0~1) N00(0~15)
+ - ∗
/
DEL END
NO Y0(0~7) C000(0~107)
(SET KEY)
00M0
[M]
+00009800.0~ +00010000.0
Set the specified output data for recording and displaying the results of
arithmetical operation to any value from 00 to 15.
Select the type of data being calculated.
A number of formula settings are used.
The first line will change according to the selection made in item 2.
Coordinates [XY], the degree of match
with the reference image [M] and the
level of light [G].
Numerical calculations [NC]
Constant [C]
Note: Please use a smaller number for the number of formulas at N (00 to 15)
than that used for 1 CALC. RESULT N (00 to 15).
Set the upper and lower limits for decisions.
Set the output conditions for the results of calculations.
Pressing the SET key will record the setting details as well as run a test.
Returns you to the [TYPE00-MEAS1 to 3] menu.
2 OBJECT TYPE
00X0 to 15X0/00Y0 to 15Y0
00M0 to 15M0
00G0 to 15G0
ABS/ /TAN/ATAN (00 to 15)
-99999999.9 to +99999999.9
The numbers ranging from 00 to 15 in front of the characters are registration numbers.
Y0
00009800.0
OK
Setting details
Selection of 2
Model 0
00X1 to 15X1/00Y1 to 15Y1
00M1 to 15M1
00G1 to 15G1
9·54
The first line of the display
Record 00 (0 to 15) model (0 to 1)
N00 (0 to 15)
ABS
TAN ATAN N00 (0 to 15)
(the second line will not be displayed)
+00000000.0 (the second line will not
be displayed)
Model 1