Setting The Criteria For Each Object Type
(1) Outline of setting the measurement program
4MEAS.0, CAMERA 1
6MEAS.0, CAMERA 2
0MEASUREMENT 1
qMEASUREMENT 2
wMEASUREMENT 3
9
(2) Halting on an NG measurement
All measurements can be halted if an NG measurement occurs whilst operating the IV-S20.
This is done by selecting item y HALT MEAS ON NG on the [OBJECT TYPE COND] menu.
[OBJECT TYPE COND]
1OBJECT TYPE NO.
tSYSTEM-IN/OUT
yHALT MEAS ON NG
uUPPER MENU
y
[TYPE00-MEAS0]
1SELECT MEAS.
2COPY
3INITIALIZATION
4MEAS. PROG. COND (TO NEXT SUB-MENU)
5EVALUATION COND (TO NEXT SUB-MENU)
6NUMERIC CAL COND (TO NEXT SUB-MENU)
7OUTPUT CONDITIONS (TO NEXT SUB-MENU)
8UPPER MENU
[TYPE00-MEAS1]
1MEAS SELECTION NO
2COMPARE IMAGES NO YES(CAM1)
3SELECT CAMERA CAM1 CAM2
4COPY
5INITIALIZATION
6MEAS.PROG. COND (TO NEXT SUB-MENU)
7EVALUATION COND (TO NEXT SUB-MENU)
8NUMERIC CALC COND (TO NEXT SUB-MENU)
9OUTPUT CONDITIONS (TO NEXT SUB-MENU)
0UPPER MENU
* Will be displayed unless "NO" is selected in item 8 SELECT CAMERA IMG (camera
selection) on the [OBJECT TYPE COND] (conditions of object type) menu.
Set the specific
conditions for each
measurement program
Set the output conditions (see
"Chapter 10: The PC Function")
00(0 ~15)
(NEXT MENU)
NO YES
HALT MEAS ON NG
(Halting on an NG
measurement)
YES
Halt all measurements if an NG evaluation occurs.
NO
Allows measurements to continue when an NG evaluation occurs.
NO MEAS-POSITION-DEVIATE
EXEC TYPE00-CAM1NO
EXEC
CHECK-DEG-OF-MATCH
DST&AGL MES. (GRAY&EDGE GRAV)
INSPECT-LEAD MEASR-BIN-AREA
CNT-BIN-OBJ LABEL-BIN-OBJ
POINT MEAS
EXEC TYPE00 MEAS1 NO
EXEC
Set the determination
conditions (testing)
Previous menu
Description
9-2
Displayed when
object type 00
is selected.
Displayed when object type
00 is selected and
measurement 1 is selected.
*
Select the camera.
Set the method for
numeric calculation
(testing)