SECTION THREE - Interfacing
At this prompt
SET UP
INTERVAL
ITEM 1
ITEM 2
ITEM 3
ITEM 4
ITEM 5
Page 54
data output to be received by the unit. Port 1 or Port 2 of the unit, or A or
B of the 800, may be used. Wire colors refer to the unit's interface cable.
Table 8: Connection to Northstar 800 port A
800 OUTPUT
Port A
951/952 Port 1
Pin 12
brown (#3)
Pin N
blue (#1)
Table 9: Connection to Northstar 800 port B
800 OUTPUT
Port B
951/952 Port 1
Pin 7
brown (#3)
Pin H
blue (#1)
To configure the Northstar 800 for correct output format, execute COM-
MAND 83 for output port A, or COMMAND 84 for output port B. Press the
lower SELECT button until PRINTER 3 appears in the lower display, and
press ENT. Then enter the following sequence to program the output
parameters:
Table 10: Northstar 800 series output port setup
Press
149 (ENT)
1 (ENT)
13 (ENT)
26 (ENT)
31 (ENT)
40 (ENT)
0 (ENT)
* Only used if you want the waypoint to which you're navigating to be
automatically transferred to the unit's waypoint database.
For further details, you may want to refer to the Northstar 800/800X Ref-
erence Manual (Part Number GM260).
CONNECT TO EITHER
951/952 Port 2
white with brown stripe (#6)
brown with white stripe (#2)
CONNECT TO EITHER
951/952 Port 2
white with brown stripe (#6)
brown with white stripe (#2)
To output this data to the 951/952
0183 output format
(8 bits, no parity, 4800 baud)
1 second output rate
include GTD sentence in output
waypoint location*
include SRS sentence in output
include RMA sentence in output
end of sequence
951/952 INSTALLATION MANUAL Revision B
(Loran-C TDs)
(status of received signals)