Figure 45
1. Left-wheel-motor fuse—60 A
The fuse for the electrical system is located under
the main-power connectors
Figure 46
1. Main-power connectors
g282896
(Figure
46).
g296483
2. Electrical-system
fuse—175 A

Servicing the Batteries

Note:
The machine is equipped with 5 lithium-ion
batteries.
A lithium-ion battery must be disposed of or recycled
in accordance with local and federal regulations. If a
battery requires service, contact your authorized Toro
distributor for assistance.
The only user serviceable parts on a battery are the
labels. If you attempt to open the main compartment
of a battery, you will void your warranty. If you
are having problems with a battery, contact your
authorized Toro distributor for assistance.
Maintaining the Battery
Charger
Important:
All electrical repairs should be
performed by an Authorized Toro Dealer only.
The charger requires little maintenance other than
protecting it from damage and weather.
Clean the battery-charger cords and case with a
slightly damp cloth after each use.
Note:
Do not clean the dielectric grease from the
terminals.
Coil the cords when not in use.
Periodically examine the cords for damage, and
replace them when necessary with Toro-approved
parts.