Module model name read (
*1 *5
Module error collection function
*1
IP address change function
(
(Communication via Built-in Ethernet Port))
Local device batch read function
CC-Link IE Field Network (
Master/Local Module User's Manual)
*5
Send points extension function
(
Page 303, Section 3.36)
Online change of inactive blocks (SFC)
Programming Manual (SFC))
Expansion of SFC step relay points (
Operation mode setting at SFC double block START
Q/L/QnA Programming Manual (SFC))
SFC comment readout instruction
Manual (SFC))
Data up to 10238 bytes can be exchanged with the
SP.SOCSND/S(P).SOCRCV(S)/S(P).SOCRDATA instructions
(
QnUCPU User's Manual (Communication via Built-in Ethernet Port))
Parameter-valid drive information (
Program cache memory auto recovery function (
3.28)
Extension of available index register range (Z0 to Z19) when Jn and Un are
used in the dedicated instruction (
the intelligent function module used)
Storage of device memory error information (Memory check function)
(
QCPU User's Manual (Hardware Design, Maintenance and
Inspection))
Storage of program error location (Memory check function) (
User's Manual (Hardware Design, Maintenance and Inspection))
Serial communication function
(Q03UD/Q04UDH/Q06UDH/Q10UDH/Q13UDH/Q20UDH/Q26UDHCPU)
(
Page 232, Section 3.23)
SFC control target block switching (
Manual (SFC))
AnS/A series compatible extension base unit
Communication using the A-compatible 1E frame (MC protocol) through built-
in Ethernet port (
MELSEC Communication Protocol Reference
Manual)
IP packet transfer function (CC-Link IE Field Network) (
User's Manual (Communication via Built-in Ethernet Port))
Own station number setting function for CC-Link IE Field Network
(
MELSEC-Q CC-Link IE Field Network Master/Local Module User's
Manual)
Writing/reading data to/from refresh devices with the specified station
*1
number
(
MELSEC-Q/L Programming Manual (Common Instruction))
466
Function
Page 296, Section 3.33)
(
Page 297, Section 3.34)
QnUCPU User's Manual
*1
(
Page 301, Section 3.35)
MELSEC-Q CC-Link IE Field Network
(CC-Link IE Controller Network module)
*1
(
MELSEC-Q/L/QnA
Page 343, Section 4.2)
*1
(
MELSEC-
*1
(
MELSEC-Q/L/QnA Programming
*1
Page 42, Section 2.1.2)
Page 251, Section
Manuals for the network module and
MELSEC-Q/L/QnA Programming
QnUCPU
*1 *5
Function
Serial number
version
(first 5 digits)
"11043" or later
"11082" or later
"12012" or later
"12052" or later
B
"12122" or later
"13022" or later
QCPU
"13042" or later
"13062" or later
"13102" or later
"14022" or later
"14042" or later
Programming tool version
GX Works2
Version 1.15R
or later
Version 1.12N
or later
Version 1.31H
or later
Version 1.40S
or later
Version 1.40S
or later
Version 1.62Q
or later
Version 1.73B
or later
Version 1.77F
or later
Version 1.87R
or later
*10
GX Developer
Version 8.82L
or later
×
×
×
×
×
×
×

Advertisement