2.10

Settings When Program is Divided

When one sequence program is divided into multiple programs, execution conditions, such as executing a program
only once at start-up or executing a program at fixed intervals, can be set for each program.
(1) Control by multiple programs dividing one program
The CPU module can store multiple programs divided on the basis of each control unit.
This enables programming of one sequence program by two or more designers.
Control by one program
88
Control data A
Divide one program
into multiple
programs.
Control data B
Control data n
Program A
Control data A
Program B
The programs divided on
the basis of each control
Control data B
data are registered.
Program n
Control data n