Pass
The battery charge indicator shows at least one full block. Go to Step 3.
Fail
The battery charge indicator does not show at least one full block.
1.
Move the key switch to the O
2.
Disconnect the battery. Refer to
3.
Verify that the battery charger is turned off.
4.
Connect the battery charger to the battery and charge the battery.
5.
Disconnect the battery charger and reconnect the battery to the machine.
6.
Repeat Step 2.
Step 3: Test the wiring between the TEC-2402 and the traction bail
sensor.
1.
Disconnect the battery. Refer to
2.
Verify that the key switch is in the O
3.
Remove the control cover. Refer to
4.
Locate the traction bail sensor, and then unplug harness connector P26.
1. Traction bail sensor
5.
Remove the electric cover. Refer to
6.
Locate the TEC-2402 controller, then unplug harness connectors P01 and P02.
position.
FF
Connecting and Disconnecting the Battery (page
Connecting and Disconnecting the Battery (page
position.
FF
Removing the Control Cover (page
Figure 58
2. Harness connector P26
Removing the Electric Cover (page
81
14).
14).
16).
17).
g366069