Pass
The resistance readings were good.
1.
Plug in harness connectors P01 and P02.
2.
Go to Step 7.
Fail
One or more of the resistance readings was not good.
1.
Repair or replace the defective wiring.
2.
Go to
Returning the Machine to Service (page 20)
Step 7: Check for the work lights to be loading down the precharge
circuit.
1.
Verify that the key switch is in the O
2.
Verify that the battery is disconnected. Refer to
3.
Remove work lights fuse F3 from the fuse block.
1. TEC-2402 controller
4.
Connect the battery. Refer to
5.
Move the key switch to the O
6.
Look at the InfoCenter and see if the fault still repeats.
7.
Move the key switch to the O
The fault no longer
repeats.
The fault still repeats.
Step 8: Check for the motor to be loading down the precharge circuit.
1.
Verify that the key switch is in the O
2.
Verify that the battery is disconnected. Refer to
3.
Unplug harness connector P21 from the motor cable.
position.
FF
Figure 32
Connecting and Disconnecting the Battery (page
position.
N
position.
FF
1.
Troubleshoot the cabling and switch for the work lights.
2.
Go to
Returning the Machine to Service (page 20)
1.
Install fuse F3.
2.
Go to Step 8.
position.
FF
and follow the steps listed.
Connecting and Disconnecting the Battery (page
2. Fuse F3
Connecting and Disconnecting the Battery (page
42
14).
14).
and follow the steps listed.
14).
g365787