Fault 13 Internal Battery - Toro Greensmaster e1021 Diagnostic Manual

Hide thumbs Also See for Greensmaster e1021:
Table of Contents

Advertisement

Fault 13 Internal Battery

Important:
While this fault is active, the battery management system (BMS) controller keeps the
battery contactor open, not allowing battery power to go to the machine. As a result, the machine will
not respond when the key switch is turned to the O
Note:
In addition to the listed Recommended Service Actions for this fault, there is also a special tool available
with its own troubleshooting capabilities. See the
InfoCenter Display:
Fault Description
The battery management system (BMS) monitors voltage, current, and temperature conditions of the battery.
The battery CAN system supplies the fault message related to the fault.
Note:
One of the following battery-related operator advisories may have appeared on the InfoCenter before
this fault occurred. If it did, try the Recommended Service Action for that advisory code.
Advisory
Advisory
Code
Name
202
Power Save
Warn
203
Energy Saving
Mode Active
204
Energy Saving
Mode Warning
214
Battery Temp
Too Low
215
Battery Temp
Too High
216
Battery Voltage
Too High
Conditions for Setting the Fault
The internal battery fault may be reported for communication, voltage, current, and temperature out of range
conditions.
Note:
The Samsung battery and controller are not serviceable. If determined to be faulty, they must be
replaced. Breaking the tamper-proof seal on a battery or controller case voids any existing warranty that it
may have.
M/S Samsung Service Wire Harness (page 9)
Internal Battery Fault
Technical Description
Battery state-of-charge is too low
for continued operation. Machine
will shutdown in 30 seconds and
require battery charging for continued
operation.
Battery state-of-charge is too low for
normal operation. The machine will
operate with reduced functionality.
Battery state-of-charge is too low for
normal operation, warn the operator
that the machine will start operating
with reduced functionality in 30
seconds.
The machine's battery is too cold.
The machine's battery is too warm.
The battery bus voltage has risen
too high for the BMS, battery will be
shutting down. This is likely due to
excessive regeneration at full battery
state-of-charge.
position.
N
Recommended Service Action
Charge the battery.
Charge the battery.
Charge the battery.
Bring the machine indoors and let the
battery warm up.
Let the battery cool down before
resuming operation.
Do not transport the machine down
steep hills with a full charged battery.
61
in this manual.

Advertisement

Table of Contents
loading

This manual is also suitable for:

0483104861

Table of Contents