Toro Greensmaster e1021 Diagnostic Manual page 47

Hide thumbs Also See for Greensmaster e1021:
Table of Contents

Advertisement

Pass
The battery charge indicator shows at least one full block. Go to Step 3.
Fail
The battery charge indicator does not show at least one full block.
1.
Move the key switch to the O
2.
Disconnect the battery. Refer to
3.
Verify that the battery charger is turned off.
4.
Connect the battery charger to the battery and charge the battery.
5.
Disconnect the battery charger and reconnect the battery to the machine.
6.
Repeat Step 2.
Step 3: Inspect the wiring for the motor.
1.
Disconnect the battery. Refer to
2.
Unplug harness connectors P20 and P21 from the motor cables.
1. Harness connector P21
3.
Inspect the 2 motor cable connectors and the 2 harness connectors for damage, corrosion, debris, and
proper alignment of the pins inside the connectors.
Pass
The wiring inspection passed.
1.
Leave harness connectors P20 and P21 unplugged from the motor cable connectors.
2.
Leave the battery disconnected.
3.
Go to Step 4.
Fail
The wiring inspection failed. Repair or replace the worn or damaged parts. Go to
Machine to Service (page 20)
position.
FF
Connecting and Disconnecting the Battery (page
Connecting and Disconnecting the Battery (page
Figure 36
2. Harness connector P20
and follow the steps listed.
47
14).
14).
g365811