Step 5: Disconnect the traction switch.
The traction switch is also referred to as the traction bail proximity sensor.
1.
Locate the traction switch.
1. Traction switch
2. Harness connector P29.
2.
Unplug harness connector P29 from the traction switch connector.
3.
Turn on the machine by rotating the key switch to the O
4.
Look at the InfoCenter and see if the fault is still repeating.
5.
Shut off the machine by rotating the key switch to the O
The
The traction switch is not causing the fault.
fault
1.
Leave harness connector P29 unplugged.
repeats
2.
Do not install the control cover at this time.
3.
Go to Step 6.
The
The traction switch is causing the fault.
fault
1.
Install a new traction switch.
does
not
2.
Install the control cover.
repeat
3.
Install the white electric cover.
4.
Go to
Returning the Machine to Service (page 20)
Figure 21
3. Traction switch connector
4. Harness connector P43 (for the hour meter)
position.
N
position.
FF
and follow the steps listed.