3.
Press the middle button to scroll down through the faults until Clear System Faults is highlighted.
4.
Press the right button. A confirmation screen appears.
5.
Press the middle button to confirm clearing the InfoCenter fault log. An "All faults cleared" message
appears.
6.
Press the left button as needed to return to an operator information screen.
Note:
Some faults clear when you start the machine. After the fault clears, you can resume normal operation of
the machine.
If a fault repeats each time you start the machine, conduct diagnostic troubleshooting of the affected system
and related components.

Preparing for Troubleshooting and/or Testing

Note:
Refer to your machine's operator's manual for more information about controls, switches, and using
the kickstand.
CAUTION
Rings, watches, bracelets, necklaces, and other jewelry can cause an electrical shock or
become entangled with the machine.
Remove all jewelry, especially rings and watches, before doing any troubleshooting or testing.
Before performing troubleshooting and/or testing procedures on the machine, do the following steps:
1.
Park the machine on a level surface.
2.
Ensure that the traction lever is in the N
3.
Engage the parking brake.
4.
Shut off the engine and remove the key from the ignition switch.
5.
Move the kickstand into the S
6.
Disconnect the battery before servicing the machine, unless it is needed for troubleshooting or testing.
Refer to
Connecting and Disconnecting the Battery (page
The machine is now ready for testing and diagnostic work to take place.

Removing the Control Cover

The control cover must be removed to access some of the connectors on the wire harness, and some of the
machine components.
1.
Disconnect the battery. Refer to
2.
Remove the 4 fasteners that secure the control cover to the machine.
3.
Remove the control cover from the machine.
position.
EUTRAL
position.
ERVICE
Connecting and Disconnecting the Battery (page