(2) Wire and assembly of detector cables and communication cables
The wire specifications and manufacturing methods for each cable are shown below. Use the
recommended wire or equivalent parts in the following table when manufacturing the cable, and
be sure to connect all parts correctly.
Core size
2
] × one pair
[mm
0.08 × 10
0.3 × 12
Note : d is as shown in the following drawing.
Securely connect the cable shield wire to the connector grounding plate as shown in the following
drawings.
Wire core
Shield
(external conductor)
5. Connections
Outline of the core insulation
sheath (Note) d [mm]
0.9 ~ 1.27
Conductor
Cross-section of the wire core
Sheath Conductor
5 − 22
Recommended
wire model
UL20276
AWG28 10 pair
(Black)
UL1061-2464
AWG22 12 pair
(Black)
Insulation sheath
Wire core
Shield
(external conductor)
Grounding plate
Cable type
Serial bus cable
(CN1A/CN1B)
Standard detector
cable
Sheath Conductor