When Alarms And Warnings Appear In The Display - Mitsubishi Electric MDS-B-SPJ2 Series Specification Manual

Ac spindle drive unit
Table of Contents

Advertisement

11.4.2 When alarms and warnings appear in the display

(1) There is no error display, but the motor will not rotate at all.
Investigation items
1 Check the wiring
around spindle drive
unit. Also check for
loose terminal screws,
broken wires, etc.
2 Check the input
voltage.
3 Confirm all spindle
parameters.
4 Check the input
signals.
• Are the ready ON,
forward run and
reverse run signals
input?
• Particularly, the
forward run and
reverse run signals
must be input 1 sec.
or more after the
ready on signal.
• Also check if the
forward run and
reverse run signals
are ON
simultaneously.
5 Check the speed
command.
11. Troubleshooting
Investigation results
The wiring is incorrect, or there is a
loose screw or broken wire, etc.
No particular problem.
The voltage exceeds the
specification value.
The voltage is within the specification
value.
The correct value is not set.
The correct value is set.
The signals are not input, or the
sequence is incorrect. The
orientation command is input.
No particular problem.
The speed command is not input
correctly.
The speed command is correctly
input.
11 − 21
Remedy
Wire the unit correctly. Tighten the
screws. Replace the cable.
Investigate item 2, and carry out the
appropriate measures.
Return the voltage to the correct
value.
Investigate item 3, and carry out the
appropriate measures.
Set the correct value.
Investigate item 4, and carry out the
appropriate measures.
Correct the input signals.
Investigate item 5, and carry out the
appropriate measures.
Correctly input the speed command.
Replace the unit.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents