Mitsubishi Electric MDS-B-SPJ2 Series Specification Manual page 117

Ac spindle drive unit
Table of Contents

Advertisement

7.3.3 Noise filter
(1) Selection
If radio noise must be reduced, select a noise filter from the following table according to the power
supply unit model:
MDS-B-SPJ2
02, 04, 075
15
22
37
55
75
110/110C
(2) Noise filter installation position
Insert the noise filter in the unit input.
Power
distrbution box
Power
supply
(3) Specifications
Rated voltage
Name
AC
DC (V)
LF-310
LF-315
LF-320
LF-330
LF-340
LF-350
LF-360
(4) Shape and dimensions
Unit: mm
Part name
A
LF-310
180
LF-315
180
LF-320
180
LF-330
180
LF-340
180
LF-350
180
LF-360
200
7. Optional Specifications and Parts
Noise filter name (Tohoku Kinzoku)
Noise filter
Tested voltage
Rated current
AC 1 min. (V)
AC
Between case
DC (A)
terminals
250
10
250
15
250
20
250
30
250
40
250
50
250
60
• LF-300 Series
IN
Rating
nameplate
B
C
D
170
60
25
120
170
60
25
120
170
60
29
120
170
60
29
120
160
50
30
200
160
50
30
200
180
60
30
300
LF-310
LF-315
LF-320
LF-330
LF-340
LF-350
LF-360
Insulation
resistance
(MW)
500VDC
1500
> 300
1500
> 300
1500
> 300
1500
> 300
1500
> 300
1500
> 300
1500
> 300
E
F
G
H
135
150
35
135
150
35
135
150
35
135
150
35
220
240
40
220
240
40
320
340
50
7 − 10
∗ Connect to the
transformer input in
Unit
power supply units that
use the transformer.
Leakage current
Working tem-
(mA)
perature range
250V 60Hz
(°C)
< 1
− 20 ~ +55
< 1
− 20 ~ +55
< 1
− 20 ~ +55
< 1
− 20 ~ +55
< 1
− 20 ~ +45
< 1
− 20 ~ +45
− 20 ~ +45
< 1
I
J
4.5 × 7
65
4.5 × 7
65
6.5 × 9
65
6.5 × 9
65
6.5 × 9
80
6.5 × 9
80
6.5 × 9
100

Hide quick links: