(b) The load meter indication displays the percent of the load in respect to the motor's rated
output as a percent (%). The relation of the motor output capacity (kW) and load meter display
is as follows.
Overload (one minute) area
1500
3. Functions
Short time rating
Continuous rating area
3 − 7
Load meter 120%
Load meter 100%
Load meter
6000
8000
Continuous rating
×100 %
Short time rating
[r/min]