3.3 Meter output specifications

(1) Speedometer output
(a) A speedometer having the following specifications is recommended for measuring the
speedometer output.
(i) Model
(ii) Rating
(iii) Internal impedance : Approx. 10kΩ
(b) The +10VDC is output at the max. motor speed, regardless of the motor rotation direction.
(2) Load meter output
(a) A load meter having the following specifications is recommended for measuring the load
meter output.
(i) Model
(ii) Rating
(iii) Internal impedance : Approx. 10kΩ
(iv) Scale
3. Functions
: YM-8G type DC voltmeter (Mitsubishi)
: 10VDC full scale
: YM-8G type DC voltmeter (Mitsubishi)
: 10VDC full scale
3 − 6
Speedometer
Full scale
10V total
Load meter
Full scale
10V total
Motor speed
Max. speed
Red zone