Parameter
Description
number
26.11
Faulty connection out
26.12
Faulty connection op
27
Language
27.01
Language
27.02
Basic set-up at power on
28
Service
28.01
ID
28.02
Line contactor close time
28.03
TOR relay delay time
28.04
Start without start command
28.05
Step down level
28.06
Torque profile start
28.07
Torque finish
28.08
Torque tune
28.09
Torque ctrl gain
28.10
Torque PI integration time
28.11
Torque slip
28.12
Torque diff
28.13
Torque filter time
28.14
Mains lock setting
28.15
Minimum trig time
28.16
Accel adapt U start ramp
28.17
U start ramp switch level
28.18
T start ramp switch level
28.19
Stop ramp switch level
28.20
In-Line gain
28.21
Inside delta gain
28.22
Phase loss
28.23
Phase loss during TOR
28.24
Phase loss trip time
28.25
Phase loss trip angle 1
28.26
Phase loss trip angle 2
28.27
Bad network quality
28.28
Low supply voltage
28.29
High current fault
28.30
Shunt fault
28.31
Short circuit thyristor
28.32
Open circuit thyristor
28.33
Thyristor overload
28.34
Heatsink over temp
28.35
Faulty connection
28.36
Faulty usage
28.37
Close bypass curr lvl
28.38
Simulation motor
Setting range
Eventgroup 0 ... 6
Stop-Manual, Stop-Automatic
English, Spanish, Finnish, French, Italian
Dutch, Polish, Portuguese, Russian, Swedish
Turkish, Chinese (simplified Chinese), Arabic
Czech, German
Yes, No
Invalid ID, 30, 37, 45, 60, 72, 85, 105, 142, 170,
210, 250, 300, 370, 470, 570, 720, 840, 1050,
1250
0 ... 65535 ms
0.0 ... 300.0 s
On / Off
10 ... 100%
Constant setpoint, Linear ramp,
Progressive curve, High inertia curve
30 ... 500%
0 ... 1000%
0.01 ... 10.00
0.001 ... 10 s
0.1 ... 100%
0.1 ... 100%
0.01 ... 100 s
Automatic lock, 50 Hz manual lock
60 Hz manual lock
0.0 ... 1.0 ms
On / Off
10 ... 100%
10 ... 100%
10 ... 100%
0.0 ... 30.0
0.0 ... 30.0
On / Off
On / Off
20 ... 4000 ms
1 ... 240
1 ... 240
On / Off
On / Off
On / Off
On / Off
On / Off
On / Off
On / Off
On / Off
On / Off
On / Off
0.5 ... 4.0 x I e
M3AA 100L 2 (Ie = 5.2 A), M3BP 112M 4
(Ie = 7.4 A), M2AA 180MLA 6G (Ie = 29.3 A),
M2AA 180MLB 4G (Ie = 39.9 A), M3AA 250SMA
8 (Ie = 62.3 A), M3AA 200MLB 2 (Ie = 59.2 A),
M2AA 225SMA 2G (Ie = 74.7 A), M2BP 250SMA
4G (Ie 96.6 A), M2BA 280SMB 2L (Ie = 144.9 A),
M2BA 315SMB 4L (Ie = 221.8 A), M2BA
315MLA 2L (Ie = 319.6A), M4BP 200MLB 2G (Ie
= 59.3 A),
M3BP 315LKB 4K (Ie = 330.4 A), M3BP
315MLA 2M (Ie = 255.4 A),M3BP 280MLA 4M
(Ie 151.5 A),
M3BP 355SMC 6K (Ie = 325.6 A),
1SFC132081M0201
Number of
Fieldbus
decimals
ID
0
282
0
283
0
173
0
284
0
171
0
175
1
286
0
287
0
9
0
10
0
17
0
11
2
12
3
13
1
14
1
15
2
16
0
-
3
-
0
290
0
-
0
-
0
-
1
-
1
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
0
-
1
-
0
29
| Installation and commissioning manual | Functions
Default value
Actual
setting
0000001
Stop-Manual
English
Yes
-
245 ms
0.0 s
Off
80%
Linear ramp
100%
100%
0.02
0.004 s
1.0%
2.0%
0.02 s
Automatic lock
7
0.208 ms
Off
22%
30%
52%
0.0
3.0
On
On
500 ms
12
70
On
On
On
On
On
On
On
On
On
On
1.2 x I e
M3AA 250SMA
8
(Ie = 62.3 A)
141