■ Adjusting the Staple-Free Binding Position
<Use case>
• When the staple-free binding position in the staple-free binding mode.
<Procedure of adjustment>
NOTE:
After the setting value is changed, write the changed value in the service label.
1. Adjust the staple-free binding position by the following service modes.
• SORTER > ADJUST > FR-STP-Y
Adjustment range: -20 to 15 (Unit: 0.1mm)
As the value is changed by 1, the staple position moves by 0.1 mm.
+: Toward rear
-: Toward front
Feed Direction
+
−
Feed Direction
161
5. Adjustment