8.2.2

Basic setting for winding diameter calculation

Pr.
Name
1243
Gear ratio numerator
R600
(follower side)
1244
Gear ratio denominator
R601
(driver side)
1247
Winding diameter change
R000
increment amount limit
1248
Winding diameter change
R001
limit disable time
Block diagram
Line speed
command selection
=
Pr.291
Terminal JOG single-phase
pulse train input
0
Pr.291
Pr.862
Encoder pulse train input
(FR-A8TP)
Encoder pulse train input
(FR-A8AP/A8AL)
Pr.862
3
Terminal 2
4
Terminal 4
Pr.362
5
Terminal 1
6
Terminal 6
FR-A8AL pulse train input (PP, NP)
Initial value
1
1
9999
0 s
Line speed
acceleration/deceleration
1, 11, 21, 100
Pulse train calibration
Input pulse
Pr.279,
Pr.384
Pr.281 to Pr.283
= 0, 10, 20
=
0
Pulse train calibration
Pr.279,
Pr.281 to Pr.283
= 1
Primary delay filter
Pr.74, Pr.822, Pr.832
Pulse train calibration
Pr.279,
Pr.281 to Pr.283
WINDING DIAMETER COMPENSATION FUNCTION
Winding diameter calculation setting
Setting
range
1 to 65534
Set a gear ratio for a reduction-gear-equipped motor.
1 to 65534
Set the maximum amount of change in each winding
0 to 9.998 mm
diameter calculation.
9999
Winding diameter calculation invalid
Set the waiting time to start limiting the change
0 to 100 s
increment amount after the winding diameter
calculation is started.
0
Primary delay filter
1
Pr.284
Primary delay filter
2
Pr.362
Pr.284
3 to 6
Analog calibration
Pr.278 to Pr.281
Primary delay filter
7
Pr.284
9999
0
Description
Unit switchover
Actual line speed
Pr.358