Winding/Unwinding Shaft Selection; Tension Feedback Setting - Mitsubishi Electric A800 Plus Series Function Manual

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

6.5.2

Winding/unwinding shaft selection

Select whether the target roll is a winding shaft or unwinding shaft.
Pr.
Name
1230
Winding/unwinding selection
R002
Winding/unwinding selection (Pr.1230)
• Use Pr.1230 Winding/unwinding selection to select whether the target roll is a winding shaft or unwinding shaft.
• The initial diameter of the winding shaft is selected according to whether the operation is winding or unwinding.
Pr.1230
Winding/unwinding selection
setting
0
Winding
1
Unwinding
6.5.3

Tension feedback setting

Set parameters for tension feedback.
Select the input interface (analog input terminal) used for inputting tension feedback to the inverter.
Pr.
Name
363
Dancer / tension sensor
R102
feedback input selection
1136
Tension sensor feedback
R330
voltage/current bias
1137
Tension sensor feedback
R331
bias
1138
Tension sensor feedback
R332
voltage/current gain
1139
Tension sensor feedback
R333
gain
Dancer / tension sensor
1227
feedback input filter time
R103
constant
∗1
The setting range varies depending on the Pr.1401 setting.
PID set point
• Use a commanded tension value after taper compensation to set the set point for tension feedback. Select the tension
command input method in Pr.804 Tension / Torque command source selection.
NOTE
• Refer to
page 118
Tension feedback input selection (Pr.363)
• Use Pr.363 Dancer / tension sensor feedback input selection to select the input terminal for tension feedback.
Pr.363 setting
3
Terminal 2 (0 to 100%) (0 to 5 VDC)
4
Terminal 4 (20 to 100%) (4 to 20 mA)
5 (initial value)
Terminal 1 (-100 to 100%) (0 to ±10 VDC)
6
Terminal 6 on the FR-A8AZ (-100 to 100%) (0 to ±10 VDC)
∗1
The input specification in the initial setting is indicated.
Initial value
0
0
1
Minimum roll diameter
Maximum roll diameter
Initial value
3
4
5
9999
6
9999
0%
0 to 100%
0 N
0 to 100 N
100%
0 to 100%
100 N
0 to 100 N
∗1
0
0
0.01 to 5 s
for Pr.804 and
page 124
for the taper function.
Input terminal
∗1
∗1
∗1
TENSION SENSOR FEEDBACK TORQUE CONTROL
Tension sensor feedback torque control details
Setting
range
Winding
Unwinding
Initial roll diameter
Setting
range
The measured value is input through terminal 2.
The measured value is input through terminal 4.
The measured value is input through terminal 1.
The measured value is input through terminal 6 on the
FR-A8AZ.
No function
Set the bias voltage (current) in % for analog input.
Set the tension feedback bias value for analog input.
∗1
Set the gain voltage (current) in % for analog input.
Set the tension feedback gain value for analog input.
∗1
Without filter
Set the primary delay filter for the tension feedback
input value.
∗1
Description
Description
149