Parameter List; Parameter List (By Parameter Number) - Mitsubishi Electric A800 Plus Series Function Manual

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Parameter list (by parameter number)

2

PARAMETER LIST

2.1
Parameter list (by parameter number)
For simple variable-speed operation of the inverter, the initial values of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter's setting, change and check can be made
on the operation panel (FR-DU08).
NOTE
Simple
Simple
Simple
indicates simple mode parameters. Use Pr.160 User group read selection to indicate the simple mode parameters
only (initial setting is to indicate the extended mode parameters).
• The changing of the parameter settings may be restricted in some operating statuses. Use Pr.77 Parameter write selection
to change the setting of the restriction.
• Refer to
page 217
Pr.
Pr.
group
0
G000
Torque boost
1
H400
Maximum frequency
2
H401
Minimum frequency
3
G001
Base frequency
Multi-speed setting (high
4
D301
speed)
Simple
Simple
Simple
Multi-speed setting (middle
5
D302
Simple
Simple
Simple
speed)
Multi-speed setting (low
6
D303
Simple
Simple
Simple
speed)
7
F010
Acceleration time
8
F011
Deceleration time
Electronic thermal O/L
9
H000
relay
Simple
Simple
Simple
DC injection brake operation
10
G100
frequency
DC injection brake operation
11
G101
time
DC injection brake operation
12
G110
voltage
13
F102
Starting frequency
14
G003
Load pattern selection
15
D200
Jog frequency
Jog acceleration/deceleration
16
F002
time
17
T720
MRS input selection
18
H402
High speed maximum frequency
19
G002
Base frequency voltage
Acceleration/deceleration
20
F000
reference frequency
Acceleration/deceleration time
21
F001
increments
Stall prevention operation level
22
H500
(Torque limit level)
10
PARAMETER LIST
for instruction codes for communication and availability of Parameter clear, all clear, and Parameter copy.
Name
Setting range
Simple
Simple
Simple
0 to 30%
Simple
Simple
Simple
0 to 120 Hz
Simple
Simple
Simple
0 to 120 Hz
0 to 590 Hz
Simple
Simple
Simple
0 to 590 Hz
0 to 590 Hz
0 to 590 Hz
0 to 3600 s
Simple
Simple
Simple
0 to 3600 s
Simple
Simple
Simple
0 to 500 A
0 to 3600 A
0 to 120 Hz, 9999
0 to 10 s, 8888
0 to 30%
0 to 60 Hz
0 to 5, 12 to 15
0 to 590 Hz
0 to 3600 s
0, 2, 4
0 to 590 Hz
0 to 1000 V, 8888, 9999
1 to 590 Hz
0, 1
0 to 400%
Minimum
setting
increments
0.1%
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.01 Hz
0.1 s
0.1 s
0.01 A
∗2
∗2
0.1 A
∗3
∗3
0.01 Hz
0.1 s
0.1%
0.01 Hz
1
0.01 Hz
0.1 s
1
0.01 Hz
0.1 V
0.01 Hz
1
0.1%
Initial value
Refer
Customer
to
FM
CA
setting
page
6%
∗1
4%
∗1
3%
∗1
∗17
2%
∗1
1%
∗1
120 Hz
∗2
∗17
60 Hz
∗3
0 Hz
∗17
60 Hz
50 Hz
∗17
60 Hz
50 Hz
∗17
30 Hz
∗17
10 Hz
∗17
5 s
∗4
∗17
15 s
∗5
5 s
∗4
∗17
15 s
∗5
Inverter rated
∗17
current
3 Hz
∗17
0.5 s
∗17
4%
∗6
2%
∗6
∗17
1%
∗6
0.5 Hz
∗17
0
∗17
5 Hz
∗17
0.5 s
∗17
0
∗17
120 Hz
∗2
∗17
60 Hz
∗3
9999
8888
∗17
60 Hz
50 Hz
∗17
0
∗17
150%
∗17

Advertisement

Table of Contents
loading

Table of Contents