Mitsubishi Electric A800 Plus Series Function Manual page 94

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Pr.
Name
1288
Data table winding diameter 1
R510
1289
Data table taper ratio 1
R511
1290
Data table winding diameter 2
R512
1291
Data table taper ratio 2
R513
1292
Data table winding diameter 3
R514
1293
Data table taper ratio 3
R515
1294
Data table winding diameter 4
R516
1295
Data table taper ratio 4
R517
1296
Data table winding diameter 5
R518
1297
Data table taper ratio 5
R519
Block diagram
Dancer tension setting
Pr.430=9999
Dancer tension setting
Pr.430
Analog terminal input
Pr.364
Pr.430=9999
Connection diagram
Input with the potentiometer
Pr.1285="4"
Pr.1287="9999"
Pr.158="19"
∗1
Terminal 6 is equipped to the plug-in option FR-A8AZ.
Initial value
9999
0%
9999
0%
9999
0%
9999
0%
9999
0%
Dancer tension
setting calibration
Dancer tension setting
(after calibration) (%)
Pr.427
Pr.426
0%
100%
Dancer tension setting (%)
Line speed command
Dancer signal
Taper ratio setting
1 W 2 kΩ
1 W 2 kΩ
Dancer feedback speed control details
Setting
range
0 to 6553 mm,
9999
0 to 100%
0 to 6553 mm,
9999
0 to 100%
0 to 6553 mm,
9999
Set the data table profile for the taper mode selection.
0 to 100%
0 to 6553 mm,
9999
0 to 100%
0 to 6553 mm,
9999
0 to 100%
Taper function
Taper control
Pr.1287=9999
Taper ratio setting
Pr.1287
Analog terminal input
Pr.1285
Pr.1287=9999
FR-A800-R2R
2 (0 to 10 V)
1 (±10 V)
Tension setting
10E
AM
4
5
5
6 ∗1
FR-A8AZ
DANCER FEEDBACK SPEED CONTROL
Description
Clamping
Analog output
signal for dancer
tension control
Electro-pneumatic
converter
3
93