Analog Output Signal Function For Dancer Tension Setting - Mitsubishi Electric A800 Plus Series Function Manual

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Dancer feedback speed control details
3.5.16
Analog output signal function for dancer tension
setting
The dancer tension command can be used for controlling the dancer roll using an air cylinder. The dancer tension command
can be output through terminal FM/CA or terminal AM.
The dancer tension setting can be input by setting parameters or through an analog input terminal.
By setting the dancer tension, taper ratio, and winding diameter at taper start, the analog output signal for dancer tension
control can be calculated based on the winding diameter determined by winding diameter calculation.
Pr.
Name
74
Input filter time constant
T002
364
Dancer tension setting input
R411
selection
426
Dancer tension setting bias
R412
427
Dancer tension setting gain
R413
430
Dancer tension setting
R410
826
Torque setting filter 1
T004
836
Torque setting filter 2
T006
1284
Taper mode selection
R500
1285
Taper setting analog input
R501
selection
1286
Winding diameter at taper
R503
start
1287
Taper ratio setting
R502
92
DANCER FEEDBACK SPEED CONTROL
Setting
Initial value
range
1
0 to 8
3
4
5
9999
6
9999
0%
0 to 200%
100%
0 to 200%
1 to 100
100
9999
0 to 5 s
9999
9999
0 to 5 s
9999
9999
0
1
0
2
3
4
3
4
9999
5
6
9999
0 to 6553 mm
9999
9999
0 to 100%
0
9999
Description
The primary delay filter time constant to the analog
input is selectable. A larger setting results in slower
response.
The tension setting is input through terminal 2.
The tension setting is input through terminal 4.
The tension setting is input through terminal 1.
The tension setting is input through terminal 6 (FR-
A8AZ).
No function
Set the bias tension.
Set the gain tension.
Set the maximum value for dancer tension setting.
Tension setting through analog input terminal
Set the primary delay filter time constant to the analog
input.
As set in Pr.74.
Second function of Pr.826 (enabled when the RT signal
is ON)
As set in Pr.826 or Pr.74.
No taper
Linear taper profile
Hyperbolic taper profile 1
Hyperbolic taper profile 2
Data table profile
The taper ratio is input through terminal 2.
The taper ratio is input through terminal 4.
The taper ratio is input through terminal 1.
The taper ratio is input through terminal 6 (FR-A8AZ).
No function
Set the winding diameter to start taper control.
Taper control is started at the minimum winding
diameter.
Set the taper ratio.
The taper ratio is set through the analog input terminal.

Advertisement

Table of Contents
loading

Table of Contents