Mitsubishi Electric A800 Plus Series Function Manual page 191

Hide thumbs Also See for A800 Plus Series:
Table of Contents

Advertisement

Roll to roll dedicated I/O signal
List of input signals with validity status by control mode (function)
Pr.178 to
Pr.189
setting
0
Low-speed operation command
1
Middle-speed operation command
2
High-speed operation command
8
15-speed selection
Tension PI gain tuning start / forced
81
end
100
PID integral term reset input
101
PI control switchover
102
Offset displacement storage
103
Integral term activation selection
104
Reel change
Acceleration/deceleration time
105
selection 1 for line speed command
Acceleration/deceleration time
106
selection 2 for line speed command
107
Minimum/maximum winding
diameter selection
108
109
Stored winding diameter clear
111
Inertia compensation acceleration
112
Inertia compensation deceleration
Inertia compensation second
113
acceleration/deceleration time
114
Tension control selection
Winding diameter compensation
115
selection
116
PID compensation disabled
117
Winding length clear
120
PID gain switchover 1
121
PID gain switchover 2
122
Winding diameter measurement
123
Stall mode trigger
Speed control proportional gain
124
disabled
125
Line speed / tension command input
126
Two-way operation
: Valid, —: Invalid
190
ROLL TO ROLL FUNCTION RELATED PARAMETERS
Signal name
RL
RM
RH
REX
PGT
X100
X101
X102
X103
X104
X105
X106
X107
X108
X109
X111
X112
X113
X114
X115
X116
X117
X120
X121
X122
X123
X124
X125
X126
Tension
Dancer
sensor
feedback
feedback
speed
speed
control
control
Tension
Tension
sensor
sensorless
feedback
torque
torque
control
control
Winding
diameter
calculation